Axiomtek ICO300 Manual do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 58
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
ICO300 Series User’s Manual
Introduction
4
1.2.11 DIO (ICO300-DIO)
One DB9 female connector supports 8 bits TTL level programmable digital
input/output
Pin
Signal
1
DIO0
2
DIO1
3
DIO2
4
DIO3
5
DIO4
6
DIO5
7
DIO6
8
DIO7
9
GND
1.2.12 WatchDog Timer (WDT)
1~255 seconds or minutes; up to 255 levels.
1.2.13 Restore BIOS Optimal Defaults (JP2)
Put jumper clip to pin 2-3 for a few seconds then move it back to pin 1-2. Doing
this procedure can restore BIOS optimal defaults.
1.2.14 System LED
There are showed the LEDs indicators and functional descriptions.
LED Name
Description
Color
ACT
Indicate the storge status and its flashing when storge
access.
Green
PWR
Indicate the Power status. When the DC input is acceptable,
the LED will ON.
Yellow
Function
Setting
Normal (Default)
1-2 close
Restore BIOS optimal defaults
2-3 close